Skip to main content
24/7 emergency service available
Hands leafing through a printed technical report with an orange-yellow strip and a navy footer on a wooden table
To view · fictional case

Sample electrical report

This sample report shows how an Elektra Experts report is built. It is a fictional case: buyers of a 1974 house, an RCD that keeps switching off and a burning smell in the attic. Below you can see all six pages, with an English explanation of each part.

Real structure and layout · names, address and measurements are invented

Request an investigation

✓ Fictional case  |  ✓ Real structure and layout  |  ✓ Six pages  |  ✓ Explained in English

Pages 1 and 2

The conclusions first, then the facts

The sample report, like our real reports, is written in Dutch. It opens with who, what and where: client, inspection address, reference and reason for the investigation. Directly below is the In het kort box (in brief): the main conclusions in one place, so a seller, insurer or lawyer immediately knows what it is about.

Page 2 contains the feitelijke vaststellingen (factual findings), without interpretation and with references to the photos in the appendix. Then come the metingen (measurements): the result and assessment of each one. In this sample report that includes an insulation resistance of 0.4 MΩ, where at least 1.0 MΩ is required.

Page 1 of the sample report: header details, reason for the investigation and the navy In brief box with five conclusions
Page 2 of the sample report: factual findings with photo references and a table of five measurements
Page 3 of the sample report: the technical cause in four steps and the long-term or recent assessment
Pages 3 and 4

The cause, the assessment and the grounds

Page 3 sets out the technische oorzaak (technical cause), step by step: from a push-in connector with too little contact pressure to charred insulation and an RCD that trips. Then the question that matters in a purchase dispute: a long-term process or a recent event? The traces that point to a longer period are set against those that would point to a recent event.

Page 4 gives the grondslag van de afkeur (grounds for rejection): for every finding the matching NEN 1010 clause, so any expert can check it. This part ends with concrete advies voor herstel (repair advice) and what to do until then.

Page 4 of the sample report: table of six rejection points with NEN 1010 clauses, followed by the repair advice
Pages 5 and 6

Conclusion, independence and the photo appendix

Page 5 makes clear what the report does and does not do: it describes the technical situation and does not judge liability. Questions are answered in a technical supplement, and there is a statement of independence. Page 6 is the photo appendix: every finding with a numbered photo and caption. In this sample report those are illustrations; a real report contains only photos taken during the inspection itself.

Page 5 of the sample report: conclusion, independence and an explanation of this demo report
Page 6 of the sample report: photo appendix with four numbered images and captions
Reading a Dutch report

The Dutch terms you will see, in English

Our reports are in Dutch because the seller, insurer or lawyer usually reads Dutch. This list helps you follow along; we always explain the findings to you in English as well.

In the reportIn EnglishWhat it means
In het kortIn briefThe main conclusions on one page
Feitelijke vaststellingenFactual findingsWhat was observed, without interpretation
MetingenMeasurementsEach measurement with its result and assessment
Technische oorzaakTechnical causeHow the damage came about, step by step
Grondslag van de afkeurGrounds for rejectionThe NEN 1010 clause behind each finding
Advies voor herstelRepair adviceWhat needs to be done to make it safe
GroepenkastFuse boxThe consumer unit with all circuits
AardlekschakelaarRCDSwitches off when current leaks to earth
InstallatieautomaatCircuit breakerSwitches off when a circuit is overloaded
LasdoosJunction boxA box where wires are joined
IsolatieweerstandInsulation resistanceHow well the wiring is insulated
What it gives you

One report, three readers

For you

Conclusions up front, concrete repair advice, and an explanation in English. You know exactly what is going on and what the next step is.

Request an investigation

For the repair

The installer sees exactly what needs repairing. You choose who carries out the repair.

Report for your insurer

Need a report yourself? Call 085 505 5457

Request an investigation
Frequently asked questions

Frequently asked questions about the sample report

Is this a real report?

No. The structure and layout are the same as our real reports, but the case, names, address, dates and measurements are fictional. That way we can show what a report looks like without using any client's details.

Why is the sample report in Dutch?

Because our real reports are in Dutch too: they are usually read by a Dutch seller, insurer or lawyer. We explain every report to you in English, and the glossary on this page helps you follow the main terms.

Will my report look exactly like this?

The structure will: header details, In brief, findings, measurements, cause, grounds, repair advice and photo appendix. The content and length depend on your situation.

Does a real report contain real photos?

Yes. A real report contains only photos taken during the inspection itself, each with a caption and a reference from the text. In this sample report they are illustrations.

How quickly do I receive a report?

Usually within about an hour of completing the inspection.

How much does a report cost?

The price is on request, depending on the type of report and the size of the installation. You always receive a price in advance.

Request an investigation

A report for your own situation

Tell us briefly what is going on. We will advise which report fits and contact you about the price and the planning. From abroad, call +31 85 505 5457.

8+
Years of experience

Recognised installation company

A+
NEN certified

Recognised installation company

Request an investigation

Reports

Which report fits your situation?

Questions about the sample report?

Call us. We are happy to explain what a report for your situation would look like.

Call 085 505 5457